What does Corvis measure? - Dr. Mehrdad Mohammadpour
مقاله تخصصی

What does Corvis measure? - Dr. Mehrdad Mohammadpour

3 weeks ago
984 بازدید
Professor Mehrdad Mohammadpour

Professor Mehrdad Mohammadpour

تهران

Cornea surgeon and fellowship, professor at Tehran University

What does Korvis measure?

Using Scheimpflug dynamic imaging, Corvis records the response of the cornea to a standard air pulse and produces 4 groups of data:

A) Motion parameters and deformation
• A1/A2 velocity
• Deformation amplitude
• Peak distance
• Radius of curvature during deformation

b) IOP and Tonometry parameters
• bIOP (biomechanically corrected IOP)

c) Combined biomechanical parameters
• CBI (Corvis Biomechanical Index)
• TBI (Tomographic-Biomechanical Index; combination of Corvis + Pentacam)

d) estimated stiffness modulus
• Stress–Strain Index (SSI)
which is an alternative to Young's modulus in stroma.

2) Are these the real biomechanics of the cornea?

Corneal biomechanics in the full sense includes:
• Young's modulus
• Hysteresis
• Viscoelastic behavior
• Real stress-strain models
• Collagen lamellar architecture
• Non-IOP-dependent behavior
• Nonlinear tissue response (nonlinear elasticity)

Corvis does not measure any of these directly.
Instead:
• Creates an external stimulus (air puff)
• Films the dynamic response of the cornea
• From this response, tissue behavior is inferred

So it is not the most accurate biomechanical measurement, but a proxy with high reliability.

3) How close is Corvis to real biomechanics?

Studies show:
• SSI has a significant correlation with true stroma stiffness
• CBI and TBI are the best screening tools for keratoconus and ectasia
• But true viscoelastic behavior cannot be measured with Corvis

To fully measure biomechanics, you need:
• ex vivo stress–strain tests
• Brillouin microscopy methods
• FEM modeling or AI-based reconstruction aids

🎯 final summary

Corvis:
• ✔️ measures the dynamic response of the cornea
• ✔️ provides useful biomechanical indicators
• ✔️ is excellent for KC diagnosis and LASIK risk assessment
• ❌ does not directly measure the actual biomechanics of the tissue
• ❌ it is not possible to measure viscoelasticity and exact tissue moduli
Comparative text: Corvis position in measurement Biomechanics of the cornea

Corvis (Corvis ST) is one of the most advanced non-contact tools for evaluating corneal behavior, but it should be noted that this device does not directly measure the true and intrinsic biomechanics of the cornea. What Corvis does is record the dynamic response of the cornea to a standard air pulse; Therefore, the data it produces are actually functional and inferential indicators, not direct measurements of tissue properties.

Real corneal biomechanics include fundamental parameters such as Young's modulus, hysteresis, viscoelastic behavior, stress-strain properties, and collagen lamellar arrangement. These properties can only be directly measured by laboratory methods or technologies such as Brillouin microscopy. Corvis does not measure such parameters; Rather, it estimates relative stiffness and stability patterns from the appearance of the cornea when it changes shape.

However Corvis is a very valuable tool because it can provide biomechanical-clinical indicators: indicators such as SSI, CBI and TBI extracted from dynamic data and their combination with topography. These indices perform particularly well in diagnosing subclinical keratoconus, assessing the risk of post-LASIK ectasia, and monitoring the crosslinking effect. Therefore, the value of Corvis is that it measures clinically applicable biomechanics, not fundamental tissue biomechanics.

In other words:
Corvis shows the mechanical behavior of the cornea in practice, not the intrinsic properties of the tissue. The two are related, but not the same. This difference should be taken into account when interpreting data and making treatment decisions

اشتراک‌گذاری:

مقالات مرتبط

مقالات دیگر از Professor Mehrdad Mohammadpour

56 مقاله
Smile is safer or femtolysic - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Smile is safer or femtolysic - Dr. Mehrdad Mohammadpour

Smile is safer or femtolysic : Let us examine these two propositions from the perspective of the...

2 weeks ago بخوانید
Serious disadvantages of cheap and low-quality LASIK - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Serious disadvantages of cheap and low-quality LASIK - Dr. Mehrdad Mohammadpour

Serious disadvantages of cheap and low-quality LASIK:The decrease in public interest in refractiv...

3 weeks ago بخوانید
Thickening of thin cornea - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Thickening of thin cornea - Dr. Mehrdad Mohammadpour

Technique of thickening thin cornea has come true:Lenticule technique derived from SMILE operatio...

3 weeks ago بخوانید
FLACIK - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

FLACIK - Dr. Mehrdad Mohammadpour

The revised and correct definition of FLACIK in the treatment of keratoconus (invented by Dr. Meh...

3 weeks ago بخوانید
Transplantation of corneal artificial endothelial cells - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Transplantation of corneal artificial endothelial cells - Dr. Mehrdad Mohammadpour

Corneal Artificial Endothelial Cell Transplantation:This study will be led by Professor Francis M...

3 weeks ago بخوانید
READ technology - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

READ technology - Dr. Mehrdad Mohammadpour

READ technology is the newest method to correct presbyopia:READ technology, which stands for Refr...

3 weeks ago بخوانید
Eye color change, from advertisement to reality - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Eye color change, from advertisement to reality - Dr. Mehrdad Mohammadpour

Eye color change, from advertisement to reality Keratopigmentation (KTP): iris beauty coloring in...

3 weeks ago بخوانید
Aqualisik customized with the ultra-advanced Aquarius device - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Aqualisik customized with the ultra-advanced Aquarius device - Dr. Mehrdad Mohammadpour

Customized Aqualisik with the ultra-advanced Aquarius device:The difference between customized LA...

3 weeks ago بخوانید
Simultaneous Binocular Cataract Surgery - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Simultaneous Binocular Cataract Surgery - Dr. Mehrdad Mohammadpour

Immediate Sequential Bilateral Cataract Surgery (ISBCS) is a controversial topic in ophthalmology...

3 weeks ago بخوانید
A new method in eye surgery - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

A new method in eye surgery - Dr. Mehrdad Mohammadpour

A new method in eye surgery; Performing the first FLACIK corneal transplant operation in the worl...

3 weeks ago بخوانید
Corneal biomechanics - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Corneal biomechanics - Dr. Mehrdad Mohammadpour

Corneal biomechanics (Biomechanics) is an interdisciplinary branch that uses the laws of mechanic...

3 weeks ago بخوانید
LASIK customized with technology - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

LASIK customized with technology - Dr. Mehrdad Mohammadpour

Custom LASIK with AQUARIUZ technology (Ziemer Group)AQUARIUZ is actually the name of a new genera...

3 weeks ago بخوانید
The newest femtolysis device in the world - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

The newest femtolysis device in the world - Dr. Mehrdad Mohammadpour

The newest femtolysis device in the world:The newest and most advanced version of the Z8 family i...

3 weeks ago بخوانید
Benefits of NoTouch Customize Lasak - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

Benefits of NoTouch Customize Lasak - Dr. Mehrdad Mohammadpour

Advantages of No-Touch Customized LASEK / PRK This method is actually a combination of non-contac...

3 weeks ago بخوانید
4 common myths about ophthalmology - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

4 common myths about ophthalmology - Dr. Mehrdad Mohammadpour

4 common myths about ophthalmology 👁️ ❌ 1. "Ophthalmology is all about glasses and scoring."✔️ F...

3 weeks ago بخوانید
What is Felisik or cairs 360 - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

What is Felisik or cairs 360 - Dr. Mehrdad Mohammadpour

What is Felisik or cairs 360?One of the most logical and promising methods of corneal preservatio...

3 weeks ago بخوانید
The latest correction of presbyopia with laser - Dr. Mehrdad Mohammadpour
مطالعه بیشتر

The latest correction of presbyopia with laser - Dr. Mehrdad Mohammadpour

The latest laser presbyopia correction In the settings of the Alcon WaveLight EX500 device to run...